← Research library
ResearchMixed evidence

Fourteen EEG studies, five for entrainment and eight against it

Ingendoh and colleagues (2023) · PLOS ONE · Summary by Sentiosonics research agent
Year
2023
Stimulus
Binaural beats
Design
PRISMA-guided systematic review with dual independent screening and a quality assessment; no meta-analysis
Sample
14 studies

Summary

Almost every claim made for binaural beats rests on one assumption underneath it: that the beat pulls your brainwaves into step at the same frequency. This review went looking for the evidence that it does. Fourteen EEG studies in healthy adults met the criteria, and the result is a split: five reported findings in line with the brainwave entrainment hypothesis, eight reported the opposite, and one was mixed. The authors’ own summary is that the evidence is “inconclusive at best”.

The question was specified tightly, which is what makes the answer useful. To be included, a study had to test neurologically healthy, normal-hearing adults, use a binaural beat inside the human EEG frequency range delivered with pure carrier tones, and report EEG oscillatory measures. That excludes the much larger applied literature on mood, focus and memory, and leaves only the studies that looked directly at whether the brain follows the beat. The search returned 185 records, reruns added 59 more, and 14 survived screening and quality assessment. A second rater repeated the entire search and selection independently.

The reason there is no pooled number here matters as much as the split. The 14 studies were, in the review’s words, “very heterogeneous regarding the implementation of the binaural beats, the experimental designs, and the EEG parameters and analyses”, and the authors judged them unfit for meta-analysis. Four embedded the beats in pink noise while ten used pure tones. Stimulation ran from one minute to thirty. Only eight measured EEG after the stimulus as well as during it, and the pre- and post-measurement windows ranged from twenty seconds to ten minutes. Most collected data in a single session. So the inconsistency the review documents is partly a real disagreement about the phenomenon and partly the field never having agreed on how to look for it.

Three of the eight contradicting studies are already in our library, graded here independently and before we read this review. Goodin and colleagues found no difference in spectral power against a white-noise control at 7 Hz or 16 Hz. Gao and colleagues found no change in relative power after five minutes of delta, theta, alpha or beta beats against pink noise. López-Caballero and Escera found no effect in any major band. We grade all three unsupported. One further study in the review’s set reported higher theta power for pink noise alone than for the binaural beat condition, which is the same shape as the white-noise result in dos Anjos: a sound with no beat frequency in it moving the measure anyway.

We grade this review mixed, which is the honest label for five against eight with one in between, and the split leans against the hypothesis rather than toward it. Read with the measurement problem Duecker and colleagues set out, the picture is narrower still: even the five supportive studies mostly show a power peak at the beat frequency, and a power peak is compatible with an evoked response to each pulse as well as with an ongoing oscillation being pulled into step.

Limitations. A narrative synthesis, so there is no effect size and no confidence interval anywhere in it, and the vote-count framing it falls back on (five versus eight) treats studies of very different quality as equal. No protocol was registered, which leaves the inclusion criteria harder to audit after the fact. The review stops at EEG and says nothing about whether beats change how anyone feels or performs, which is a separate question our scorecard answers outcome by outcome. And it closed its search in 2022, so the studies we have graded since are not in it.

Our analysis

How we graded this study

Each criterion is scored 1–5. Study design and replication count double in the overall score (how we grade). Graded from: full text read.

Study designA systematic review conducted to PRISMA reporting guidelines, with a second independent rater (ESP) repeating the whole search and selection and disagreements resolved by discussion, plus a formal quality assessment of the included studies. Two things hold it below the registered reviews we hold: no protocol was registered, which the paper states plainly, and the heterogeneity of the included designs meant "the outcomes of the sample of 14 studies were not deemed qualified for a meta-analysis", so the synthesis is narrative.
Sample size185 records from the initial search plus 59 from reruns, screened down to 14 included studies. A respectable yield for a question this narrow, though the included studies are individually small single-session EEG experiments rather than trials.
Control conditionThe comparators vary across the included studies, from silence to pink noise to white noise to monaural beats, which is part of why the review could not pool them. Several of the contradicting results come from the better-controlled members of the set, including the pink-noise and white-noise comparisons.
BlindingThe review does not systematically report the blinding of its included studies, so this is scored as unknown rather than as a failure. Binaural beat EEG experiments are rarely blinded, and the three included studies we hold independently score 2 or 3 on this criterion.
Outcome measureEEG oscillatory measures throughout, which are instrument-recorded rather than self-reported. Not 5 because the review's central complaint is about these very measures: the included studies differ in which EEG parameters they compute and how they analyse them, which limits what any synthesis of them can establish.
ReplicationThe review's own conclusion, that the literature does not consistently show entrainment, rests on multiple independent research groups. Three of its contradicting studies are separately in our library and were graded `unsupported` here on their own merits: Goodin 2012 (no change against white noise), Gao 2014 (no change against pink noise) and López-Caballero 2017 (no effect in any band). This is a convergent negative result, not a single team's null.
Conflicts of interest"The authors received no specific funding for this work" and "The authors have declared that no competing interests exist", both printed in the paper. Nothing commercial rides on the result, and the data availability statement puts the extracted material in the supplementary files.
Peer review & venuePLOS ONE, peer-reviewed, open access, PMID 37205669. Submitted 14 August 2022, accepted 6 May 2023.
Overall grade · 3.8 / 5Mixed evidence

Graded by our research agent on Nov 23, 2026.

Get updates from the field

A monthly letter: new research, graded, and the claims worth checking. No hype.